Active R&D Phase
BeatioPulse™ is currently in active R&D. We are actively seeking mission-aligned investors to fund this noble project and secure global patent protection.
Investor Diligence →
BeatioPulse Cardio Neural Intelligence
Hardware & Firmware Deep Dive

4-Layer Rigid-Flex PCB Fused with INT8 On-Skin Neural Intelligence.

Engineered to eliminate clinical telemetry bottlenecks: an ultra-thin 28-gram biosensor executing real-time arrhythmia classification directly at the epidermal boundary with sub-800ms cloud synchronization.

LEAD II HARDWARE SIM 24-Bit ΣΔ ADC (TI ADS1293) • 250 / 500 Hz Telemetry
INT8 INFERENCE ACTIVE

What is the BeatioPulse Technology Architecture?

The BeatioPulse™ technology architecture combines a 4-layer rigid-flex PCB, a Nordic nRF5340 dual-core processor, an INT8 quantized neural network for local arrhythmia classification, and high-voltage defibrillation protection (IEC 60601-1 Type CF). Data relays to companion cellular hubs to achieve sub-800ms skin-to-cloud telemetry.

Silicon & Materials Engineering

Six Proprietary Hardware Innovations

Every component is engineered for medical precision, continuous comfort, and ultra-reliable 14-day telemetry.

01

4-Layer Rigid-Flex PCBA

IPC-6013 Class 3

Ultra-thin 0.15 mm DuPont Pyralux polyimide flex wings decouple physical body curvature and motion artifacts from rigid central electronics, preventing shear stress peel-off during heavy exercise or sleep.

  • Substrate: Flexible Polyimide + FR4 core stiffeners
  • Copper Weight: 1.0 oz outer signal & shielding / 0.5 oz inner rolled-annealed flex planes
  • High-Voltage Isolation: Proprietary dielectric creepage barrier meeting IEC 60601-1 Type CF standards
02

Nordic nRF5340 Dual-Core SoC

Dual ARM Cortex-M33

Asymmetric dual-core architecture separates critical biometric neural processing from RF wireless stacks. Dedicated 128 MHz core executes edge ML while 64 MHz core manages BLE 5.3 mesh relays.

  • App Core: 128 MHz ARM Cortex-M33 with 1MB Flash / 512KB RAM
  • Network Core: 64 MHz ARM Cortex-M33 running BLE 5.3 Long-Range
  • Security: Arm TrustZone & hardware cryptographic engine
03

INT8 Quantized Neural Model

On-Skin Real-Time AI

Lightweight convolutional neural network executing on-chip QRS peak detection, ventricular tachycardia (VT) identification, and motion artifact suppression without cloud round-trip delay.

  • Quantization: INT8 fixed-point (sub-12ms inference window)
  • Dataset Validation: 100,000+ annotated beats (MIT-BIH Database)
  • Sensitivity: 99.8% QRS peak detection accuracy
04

2,000V Defibrillation Hardening

IEC 60601-1 Defib-Proof

Proprietary high-energy transient suppression circuitry shunts high-voltage external defibrillator discharges (up to 360 Joules / 2,000V), ensuring clinician safety and device survivability.

  • Safety Standard: IEC 60601-1 Type CF defibrillation proof
  • Surge Rating: 360 Joules biphasic defibrillator discharge
  • Telemetry Recovery: Rapid signal re-acquisition after shock event
05

1,200 mAh Solid Li-MnO2 Cell

Zero-Sag 14-Day Runtime

Non-rechargeable solid primary lithium manganese dioxide chemistry delivers continuous, ultra-stable current across 14 days without bulky charging docks or mid-monitoring interruptions.

  • Capacity: 1,200 mAh @ 3.0V nominal discharge
  • Self-Discharge: < 1% cell discharge/year; 18-month validated sterile hydrogel pouch shelf-life
  • Patient Burden: Zero recharging or wire handling required
06

Medical LSR Silicone Overmold

IP68 Continuous Waterproof

Seamless biocompatible liquid silicone rubber encapsulation protects internal circuits during showering, heavy sweating, and sleep, while maximizing gas-permeability to eliminate skin maceration.

  • Waterproof Rating: IP68 (1.5m continuous submersion)
  • Biocompatibility: ISO 10993 cytotoxicity & irritation certified
  • Adhesive: Medical acrylate with breathable microporous perimeter
Engineering Benchmarks

Hardware Specifications Matrix

How BeatioPulse compares directly with legacy mail-in patches and consumer smartwatches.

Hardware Parameter BeatioPulse™ Patch Legacy Mail-In Holter (Zio) Consumer Smartwatch (Apple/Garmin)
Form Factor Weight < 28g Single-Use Patch 34g Plastic Pod 40–60g Rigid Wristband
Lead Configuration Dual-Vector Modified Lead II Single Lead Vector Single Lead (Requires 2nd hand touch)
Sampling Rate & ADC 24-Bit ΣΔ ADC (TI ADS1293) • 250 Hz / 500 Hz Selectable 200 Hz, 12-Bit 512 Hz, Optical PPG / Sporadic ECG
Telemetry Latency < 800 ms (Real-Time Cloud) 14–21 Days Post-Mail Bluetooth Sync to Phone Only
Defibrillator Hardening 2,000V (IEC 60601-1) Not rated / Remove in ER Destructive damage
Continuous Wear Duration 14 Days (Zero Recharging) 14 Days (Zero Recharging) 18–36 Hours (Daily Recharging)
On-Skin AI Quantization INT8 Convolutional Neural Network None (Post-hoc server processing) Heuristic algorithm on smartwatch OS
Technical & Clinical FAQ

Frequently Asked Engineering Questions

Essential answers on on-skin neural compute, biopotential vector capture, and hardware fail-safes.

Short Answer: No. BeatIO Pulse is engineered as an Ambulatory Event Cardiac Monitor (AECM) / Mobile Cardiac Telemetry (MCT) device, not an Emergency Department diagnostic 12-lead substitute.

Operating across a 75 mm modified Lead II dipole captures primary depolarization (P-QRS-T) to quantify AFib burden, syncopal events, and post-ablation arrhythmias. When repolarization anomalies or wide-complex tachycardias are detected, the cloud workstation flags the record to order a confirmatory 12-lead ECG. Furthermore, the onboard TI ADS1293 incorporates expansion pads to accept a snap-on 3-lead satellite harness for inpatient multi-vector monitoring.

Short Answer: A Nordic Semiconductor nRF5340 dual-core ARM Cortex-M33 SoC executing an INT8-quantized 1D-CNN with ARM CMSIS-NN DSP acceleration within a 15 mW power envelope.

A dedicated 128 MHz application core runs continuous 2.0-second inference windows in under 18 ms for real-time QRS detection and arrhythmia triage, while an isolated 64 MHz network core handles BLE 5.2 streaming. The model footprint is under 65 KB Flash and 16 KB SRAM, allowing the device to spend >98% of its duty cycle in ultra-low-power sleep.

Short Answer: The patch incorporates high-voltage transient suppression engineered to IEC 60601-1 Type CF Defibrillation-Proof standards, withstanding 2,000V / 360-joule external discharges.

High-speed TVS diodes and dielectric isolation clamp external spikes within nanoseconds, shunting high voltage away from sensitive AFE silicon, preventing skin burns under electrodes, and resuming baseline ECG tracking immediately post-shock.

Short Answer: The patch operates autonomously with on-skin AI and an internal 16 MB 3-Tier Flash Retention State Machine where life-threatening events (VFib/VTach) are write-locked and can never be overwritten.

Upon phone reconnection, high-speed 2M PHY burst resynchronization flushes critical Tier 1 telemetry first with cryptographic HMAC-SHA256 verification before clearing locks.

Explore All 21 Technical & Clinical Questions in Full FAQ Hub →

Ready to Review the Full Medical DMR?

Contact our hardware engineering and regulatory team for complete cleanroom PCBA gerbers, 13-part BOM, and ATE test point fixtures.

Explore Practice RPM Economics →